careerpasob.blogg.se

Software to connect agilent chemstation to hplc autosampler
Software to connect agilent chemstation to hplc autosampler















The Agilent 1290 Infinity Flexible Cube is an auxiliary module for the 1290 Infinity Autosampler with a built-in pump to facilitate enhanced flushing capabilities and to reduce carry-over.

software to connect agilent chemstation to hplc autosampler

  • Composition precision: <0.15 % RSD, or 0.01 min SD, whatever is greater.
  • Composition range Settable range: 0 - 100 %.
  • Gradient formation: High pressure binary mixing.
  • Compressibility compensation: Automatic, pre-defined, based on mobile phase selection.
  • Pressure pulsation: <1% amplitude or < 0.5 MPa (5 bar), whatever is greater.
  • software to connect agilent chemstation to hplc autosampler

  • Pressure operating range: Operating range up to 120 MPa (1200 bar), up to 2 ml/min, 80 MPa (800 bar) at 5 ml/min.
  • Flow accuracy: ☑ % or 10 µl/min, whatever is greater.
  • Flow precision: ≤0.07 % RSD or 0.005 min SD, whatever is greater (0.2-5.0 ml/min).
  • Settable flow range: Setpoints 0.001-5 ml/min, in 0.001 ml/min increments.
  • #Software to connect agilent chemstation to hplc autosampler series

  • Hydraulic system: Two dual pistons in series pumps with proprietary servo-controlled variable stroke design, power transmission by ball screws, smooth motion control of pistons for active damping.
  • High resolution piston movement control for smooth and reliable motion.
  • software to connect agilent chemstation to hplc autosampler

  • Two pistons in series design for increased reliability.
  • Fast defill function for improved intake and delivery performance.
  • Solvent selection for optimum flow and composition accuracy.
  • Auto tuning of the delivery cycle for compensation of elasticity and solvent volume change effects (compressibility, thermal expansion, mixing contraction).
  • Automatic purge function for ease of use and unattended preparation of the system.
  • Jet Weaver for optimum mixing performance with a minimum of delay volume.
  • Solvent selection valve for method flexibility.
  • Seal wash for continued high lifetime of pump seals for buffer applications.
  • The Binary pump is designed for highest performance, GLP compliance and easy maintenance.
  • Control and data evaluation Agilent ChemStation for LC Control and data evaluationĬan be sold as an individual component or as part of a complete stack Learn More.
  • Composition precision < 0.2 % SD, at 0.1 and 1 ml/min.
  • Composition range 1- 99 % or 5 μl/min per channel, whatever is greater.
  • Gradient formation: High-pressure binary mixing, delay volume 180 - 480 μl without mixer, 600 - 900 μl with mixer, dependent on back pressure.
  • Recommended pH range: 0 - 12.5, solvents with pH < 2.3 should not contain acids which attack stainless steel.
  • Compressibility compensation: User-selectable, based on mobile phase compressibility.
  • Setable flow range: Setpoints 0.001 - 5 ml/min, in 0.001 ml/min increments.
  • Hydraulic system: Two dual piston in series pumps with proprietary servo-controlled variable stroke drive, floating piston design and active inlet valve.
  • Pressure P ulsation : 1 MPa (10 bar,147 psi).
  • Pressure O perating R ange : Operating range up to 60 MPa (600 bar, 8700 psi) up to 5 mL/min, Operating range up to 20 MPa (200 bar, 2950 psi) up to 10 mL/min.
  • Flow A ccuracy : ☑ % or 10 µL/min whatever is greater, pumping degassed H2O at 10 MPa (100 bar).
  • Flow P recision : ≤ 0.07 % RSD, or ≤ 0.02 min SD whatever is greater, based on retention time at constant room temperature.
  • Setable F low R ange : Set points 0.001 – 10 mL/min, in 0.001 mL/min increments.
  • power transmission by gears and ball screws, floating pistons.
  • Hydraulic S ystem : Dual piston in series pump with servo-controlled variable stroke drive,.
  • (optional) is available when the quaternary pump is used with Provides enough space for four one- liter bottles.

    software to connect agilent chemstation to hplc autosampler

    It provides gradient generation by low pressure mixing. Pump comprises a high- speed proportioning valve and a pump assembly. The quaternary pump comprises an optional solvent cabinet, a vacuum degasserĪnd a four- channel gradient pump.















    Software to connect agilent chemstation to hplc autosampler